Pill stamp press manufacturer today: Usually, the movement or activity of personnel should be reduced as much as possible in the laboratory, and the door of the clean room should be closed or automatic door closers should be installed to keep it closed. Stop use immediately when the cleanliness does not meet the requirements: When the cleanliness does not meet the requirements, it should be stopped immediately, find the cause, thoroughly clean, must be verified by the cleanliness and meet the requirements, and then use again, and record the situation in the aseptic room use register, regular archival storage. Guidance and supervision of incoming foreign personnel or maintenance personnel: non-microbial room inspection personnel shall not enter the clean room (aseptic room), and foreign personnel or maintenance personnel who must enter shall be guided and supervised. Read additional details at pill stamp press.
Clean room equipment includes air purification equipment and air ventilation equipment. During the construction process, it is necessary to select the appropriate air filtration equipment according to specific practical needs. In general, the selection of air purification equipment will use coupled filtration technology to achieve the purpose of eliminating dust in the air, that is, through multiple layers of different filtration forms, to eliminate foreign particles and harmful substances in the air.
Pharmaceutical equipment includes: granulating oven, boiling dryer, wet machine, pulverizer, vibrating screen, slicer, drug frying machine, drug frying machine, tablet press, pill making machine, multi-functional extraction tank, liquid storage tank, liquid distribution tank, decompression drying oven, tilting reaction pot, capsule filling machine, bubble type packaging machine, particle packaging machine, powder packaging machine, V-type mixer, lifting feeder, etc.
Why is Proper Humidity Important in Clean Rooms? Maintaining proper humidity levels in clean rooms is crucial for several reasons: Prevention of Condensation: High humidity levels can cause condensation on surfaces, leading to potential damage to sensitive equipment or materials. Lower humidity levels prevent this issue by reducing water vapor in the air. Mold Growth: High relative humidity levels promote the growth of mold and mildew, which can negatively impact the cleanliness and functionality of clean rooms. Ensuring proper humidity levels helps prevent mold growth and associated health hazards.
The plane and space design of the clean laboratory will arrange the clean experimental area and personnel purification, equipment and material purification and other auxiliary rooms in different areas. At the same time, the comprehensive coordination effects of various technical facilities, such as experimental operation, process equipment installation and maintenance, air distribution type, pipeline layout and purified air conditioning system, are considered.
For the tuyere equipped with filter, the auxiliary air duct can be selected according to the tuyere form, that is, the straight pipe section with the same section as the tuyere and the length equal to twice the side length of the tuyere is made of hard plate, which is connected to the outside of the filter tuyere. The measuring points are evenly arranged on the outlet plane of the auxiliary air duct according to the minimum number of measuring points, and the wind speed of each point is measured with a hot ball anemometer. The air volume is determined by multiplying the average wind speed at the section of the air outlet by the net section area of the air outlet.
Many single-flow type clean rooms are designed as vertical laminar flow, so the uniformity of wind speed is very important. Only uniform vertical laminar flow can effectively eliminate particulate pollution. For non-single-flow type clean rooms, since the concept of particle control is dilution, not immediate elimination, generally speaking, the air exchange rate is far more important than the wind speed, so it is only necessary to measure the air volume. See extra details at https://www.sz-pharma.com/.
Premium pill stamp press company supplier: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.
The frame of the clean shed can be generally divided into three types: stainless steel square pass, varnished iron square pass and industrial aluminum profiles. The top and the top can be made of stainless steel steel plate, lacquered cold plastic steel plate, anti-static mesh curtain and acrylic plexiglass and other materials. Anti-static mesh curtains or plexiglass are generally used around, and FFU clean air supply units are used in the air supply unit.